Heat Sinks since 1991

  • +39 0444 551224
  • Tre-s Italiano
  • Tre-s English
PRO1260 - Heat sinks for power modules
PRO1260 - Heat sinks for power modules

Code: PRO1260
Heat sinks for power modules

Lega BxS Dimensione Peso al metro
0 [[part1]] [[part2]]
Codice KN MAX I F H
Codice KN MAX I F H
Codice KN MAX I F H
Codice KN MAX I F H
Codice KN MAX I F H
Codice KN MAX I F H

Length: 200.00 mm

Weight: 14.86 kg/m

Weight A: 0.00 kg/m

Weight B: 0.00 kg/m

Height: 72.00 mm


Forced ventilation:

Rt: 0.00

Sample length: 0.00mm

Applied power: 0.00W

Vel. Fan: 0.00m/s

Natural ventilation:

Rt 0.00

Sample width: 0.00mm

Applied power: 0.00W

PRO1260 - Heat sinks for power modules


Within this catalog, heat sinks are organized based on their shape and dimensions expressed in millimeters. Each profile is characterized by the following parameters:

  • Weight: expressed in kilograms per meter of profile length (Kg/m).
  • Length: indicated in millimeters and used for calculating thermal resistance (L).
  • Width: also in millimeters, considered for calculating thermal resistance (°C/W), applicable only to high-efficiency heat sinks.
  • Thermal Resistance in Natural Convection: expressed in °C/W with a temperature difference of 70°C (compared to an ambient temperature of 25°C).
  • Thermal Resistance in Forced Convection: also expressed in °C/W, with an air velocity of 3 m/s and a temperature difference of 50°C.

The values of thermal resistance have been determined through a thermal simulation program designed to replicate realistic conditions. In particular:

  • The heat source is uniformly distributed over approximately 50% of the dissipation surface, with central positioning on the heat sink.
  • To maximize natural convection heat dissipation efficiency, the heat sink is designed with vertical fins. For horizontal installations, it is advisable to consider an increase of approximately 20% in thermal resistance.
  • The surface of the heat sink is not subject to additional treatments.

Regarding black anodized heat sinks in natural convection, the thermal resistance is reduced by approximately 10%.

As the length of the heat sink increases, the thermal resistance decreases following a nonlinear law. The indicated values refer to the specified lengths; for different lengths, consult the “Length Correction Factor” graph to calculate the multiplication factor to be applied to the thermal resistance, both in natural and forced convection.

Quotation request
Request curves